_va = _va | 0x01 # 0000 0001 //1st bit corresponds to DI1 Son Servo Enable # P3-06 SDI Input Contact (DI) Source Control Switch Address: 030CH 030DH #(master.execute(dvc_id, cst.WRITE_SINGLE_REGISTER, 0x0218, output_value=2)) (master.execute(dvc_id, cst.WRITE_MULTIPLE_REGISTERS, 0x0218, output_value=)) (master.execute(dvc_id, cst.WRITE_SINGLE_REGISTER, 0x0102, output_value=2)) (master.execute(dvc_id, cst.READ_HOLDING_REGISTERS, 0x023c, 0x0004)) (master.execute(dvc_id, cst.WRITE_SINGLE_REGISTER, 0x023c, output_value=0))
Modbus poll 7.1 0 serial#
Changing the value of this register is equivalent to turning on or off a DI from the external hardware terminal.Ĭan set these registers, we can not directly external hardware wiring, serial communication directly controls the speed of the servo.
Modbus poll 7.1 0 software#
P4-07 is equivalent to the switch of the software input. The value written to P4-07 is 0x0011, which means that the software SDI1 and SDI5 are ON ĭigital input pin DI (DI1~DI9) Please refer to P2-10~P2-17 and P2-36 for function planning the above list is mentioned. Reading the value of P4-07 to 0x0011 means that the final DI1 and DI5 are ON. The corresponding bit is 1 for the source software SDI (P4-07), and vice versa, from the hardware DI (corresponding to Bit 0 ~ 8 of parameter P4-07) and selected by parameter P3-06. Parameter function: DI input signal can come from external hardware terminal (DI1 ~ DI9) or software SDI1 ~ 9 P4-07■ ITST Digital Input Contact Multiple Functions Address: 040EH 040FH External hardware control or internal register control This parameter determines the source of the signal input for 1 DI per bit:Ġ: The input contact status is controlled by an external hardware terminal.ġ: Input contact status is controlled by system parameter P4-07.ĭigital input pin DI function planning please refer to: Parameter function: DI source control switch P3-06 SDI input contact (DI) source control switch Address: 030CH 030DH Three registers of internal speed instructionsĪt this time, the external hardware sets the signals of DI3 and DI4, and the speed values of the three registers can be selected. The source of speed commands is divided into two categories, one for the external input analog voltage and the other for the internal parameters. Input and output terminal software settingsĭI3, DI4 factory value is 116,117 control torque The value of the register is set to 02 speed mode, then look at the input terminal The mode (control mode setting: 06) can be accessed via DI:S-P (refer to Table 7.1) Tz: Zero Torque / Internal Torque Buffer CommandĬan switch modes by external DI (Digital Input), for example, as a mix of PT/S Sz: Zero Speed / Internal Speed Buffer Command T: Torque control mode (command source is external analog voltage / internal buffer two sources, S: Speed control mode (command source is external analog voltage / internal buffer two sources, Is added to both sources and can be selected via DI:PTAS) PT: Position control mode (command source is external pulse input / external analog voltage (* pre Parameter function: RS-232 communication selection standard MODBUS or communication with ASDA-Soft P3-05 CMM communication function Address: 030AH 030BH
Modbus poll 7.1 0 manual#
Open Advanced Safety Windows Firewall.Use serial communication to control the servo speed, see the manual first. Therefore, you must set the firewall configuration of the computer to allow external clients to get access to local 502 port through the TCP protocol.
![modbus poll 7.1 0 modbus poll 7.1 0](https://img.softwaresblue.com/upload/icons/modbus-poll220-220.png)
In this lab, Modbus Slave on your computer acts as the TCP server, and the cloud-based Edge acts as the TCP client that attempts to establish a connection with the computer. Hence both active power and reactive power occupy 2 registers. In Modbus, a register contains only one 16-bit value, a 32-bit integer needs to occupy 2 registers. For active power and reactive power, set the data type to 32-bit signed integer by selecting Long AB CD as shown in the following screenshot.For voltage and current, set the data type to 16-bit signed integer by selecting Signed as shown in the following screenshot.Set the data type for the data aquisition points by right click the row and selecting Format.
Modbus poll 7.1 0 code#
In the Modbus protocol, the data aquisition point is located through the register address, and the function code is used to access the register.įrom the menu, click Setup > Slave Definition.Įnter the following simulated data collecting points.